Pressure Reducing Valves (PRVs) Series

Product drawing»

Structural drawing»

You are here: News > News Detail

Yipump Valve YK43F-16P Gas Pressure Reducing Valve Flow Coefficient and Selection Guide

2026-11-27

The flow coefficient Cv represents the volume of water in US gallons per minute that passes through a valve at a pressure drop of 1 psi. For gas service the Cv value is used together with inlet pressure outlet pressure gas specific gravity and temperature to estimate capacity. Published manufacturer data for the YK43F series list Cv values across nominal sizes from DN15 to DN500. Representative values include DN15 Cv 1 DN20 Cv 2.5 DN25 Cv 4 DN32 Cv 6.5 DN40 Cv 9 DN50 Cv 16 DN65 Cv 25 DN80 Cv 36 DN100 Cv 64 DN125 Cv 100 DN150 Cv 140 DN200 Cv 250 DN250 Cv 400 DN300 Cv 570 DN350 Cv 780 DN400 Cv 1020 and DN500 Cv 1500. These values follow a consistent progression across multiple suppliers and serve as the basis for preliminary size selection.The main pressure reducing valve product names of China Pressure Reducing Valve Network include:Large Flow Pilot Piston High Sensitivity Steam Reducing Valve,Low Temperature Reducing Valve,Piston-Type Steam Reducing Valve,Proportional-Type Reducing Valve,Pilot-Type Oversized Diaphragm High Sensitivity Reducing Valve.

The selection procedure begins with defining the required gas flow rate in normal cubic meters per hour or standard cubic feet per hour the minimum inlet pressure and the maximum allowable outlet pressure. The minimum differential pressure across the YK43F-16P must be at least 0.15 MPa for stable regulation. If the available pressure drop is below this threshold the valve may not maintain a steady outlet pressure. Using the gas sizing equation or the manufacturer capacity charts calculate the required Cv. Select the nominal size whose listed Cv is equal to or slightly greater than the calculated value avoiding excessive oversizing that can cause hunting or unstable control at low flows.

Material and application factors complete the selection. The stainless steel construction of the YK43F-16P is compatible with oxygen service when specified with appropriate cleaning and it resists corrosion in humid or mildly aggressive gas streams. The standard outlet pressure adjustment range for the 1.6 MPa rating covers approximately 0.1 to 1.0 MPa while the maximum inlet pressure should not exceed 1.6 MPa. For higher pressure classes or larger capacities alternative YK43F variants with higher nominal pressure ratings are available. Final verification should always include confirming the Cv against the actual gas composition and temperature because lighter gases such as hydrogen and helium require different correction factors than air or nitrogen. A correctly sized YK43F-16P balances capacity turndown and pressure stability ensuring reliable service across the intended operating envelope.

Do you still need to know or purchase the following pressure reducing valve products:

Kaiweixi Valve Group Co., Ltd.
Kaiweixi pressurereduce valve Contact Kaiweixi
 Zhejiang Shanliu Valve Technology Co., Ltd.
Shanliu pressurereduce valve Contact Shanliu
Shanghai Fengqi Industrial Development Co., Ltd.
FengQi pressurereduce valve Contact FengQi
Shanghai MeiYan Yi Pump & Valve Co., Ltd.
MeiYan Yi pressurereduce valve Contact MeiYan Yi