Pressure Reducing Valves (PRVs) Series

Product drawing»

Structural drawing»

You are here: News

News

Excessive Pressure Drop in Pressure Reducing Valve 2010-11-26
Fisher 627WH pressure regulator, used in anhydrous ammonia service. This valve was originally going to see up to ~750 psig and drop it down to 300 psig
pressure-reducing upstream pressure-sustaining 2010-11-26
The cascading failure is one valve closes up (for whatever reason) and the following valves see no pressure upstream so they open wide trying to maintain setpoint and not able to.
Pressure reducing valve 2010-11-26
There are a couple of things I can think of:1 - You could use "pressure regulating" valves, not pressure reducing valves. These basically throttle the flow.
Presser Reducing Valves (PRV) 2010-11-25
Self-contained pressure regulators are sometimes called pressure reducing valves or pressure control valves. This is likely the case here.
Using Pressure Reducing Valve for filter bypass 2010-11-25
We are adding a treatment system (for taste-not safety) which will have pressure drop proportional to flow.
Reducing to lower pressures 2010-11-25
The pressure regulator you need is the same technology you breathe through when you dive (you really don't want air at 230 bar in your lungs).
3 way valve 2010-11-23
Can anyone tell me how the DP across the two ports of a 3 way valve affects its control
Valve isolation tank 2010-11-23
I will connect a future line to this valve in few months. However, the tank will already be in operation.